1.0.0 - release
CambioOpenServicesIG - Local Development build (v1.0.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: https://fhir.cambio.se/StructureDefinition/ObservationBPComplex | Version: 0.9.0 | |||
| Draft as of 2026-04-13 | Computable Name: ObservationBPComplex | |||
The ObservationBPComplex profile represents the vital sign blood pressure and additional information related to the observation such as how the patient's body was positioned at the time for instance.
Therefore in comparison to ObservationBPLite, this profile captures more information besides the systolic and diastolic blood pressure values.
The profile is derived from the standard FHIR profile ObservationVitalSigns and ObservationBP which makes the profile compliant with the FHIR standardized way of communicating vital sign data.
The must support flag indicates which attributes that will be stored as part of the observation in a Cambio system.
In COSMIC this observation is mapped to the internal archetype for complex blood pressure.
| Type | Description |
|---|---|
| Rule | If the performer is Patient, the subject should be the same as given performer. |
| Rule | If either the systolic or diastolic blood pressure is not included, a value must be sent in component.dataAbsentReason. |
| Rule | The data should not be patient initiated. If patient generated, it should be ordered by a care giver and belong to a specific unit. |
| Rule | When creating a complex blood pressure observation, the status must be 'final'. |
| Rule | dateTime cannot be only date component, also time component will be needed. |
| COS version | Profile version | Required COSMIC version | Date | Description |
|---|---|---|---|---|
| 4.20.0 | 1.0.0 | 5.0.0 | May 2026 | Initial version of the profile. |
| HTTP Method | Description |
|---|---|
| POST | Used to create a blood pressure entry. If successful, the operation will return id in response. |
POST [baseURL]/ObservationUsages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | ObservationBPCore | FHIR Blood Pressure Profile Constraints: obs-6, obs-7, vs-2 |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
SΣ | 0..* | Identifier | Business Identifier for observation |
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) |
![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
![]() ![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | Representation defined by the system Fixed Value: Vital Signs |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() |
Σ | 2..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 75367002 |
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
![]() ![]() |
SΣ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made |
![]() ![]() |
SΣC | 1..1 | dateTime | DateTime for measurement Constraints: vs-1 |
![]() ![]() |
SΣ | 1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation |
![]() ![]() |
SΣC | 0..1 | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() |
time | |||
![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. |
![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Site (required) |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system |
![]() ![]() |
S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device |
![]() ![]() ![]() |
SΣ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). Fixed Value: Device |
![]() ![]() |
SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system Constraints: vs-3 |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Systolic Blood Pressure |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271649006 |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the systolic blood pressure must be within the range of 0-350 |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Diastolic Blood Pressure |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271650006 |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the diastolic blood pressure must be within the range of 0-200 |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI |
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | |
| Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1From the FHIR Standard | |
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG | |
| Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | |
| Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | |
| Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-siteFrom the FHIR Standard | |
| Observation.bodySite.coding:BodySiteSCT | required | BPBodySitehttps://fhir.cambio.se/ValueSet/bp-body-site/v1From this IG | |
| Observation.device.type | extensible | Fixed Value: Devicehttp://hl7.org/fhir/ValueSet/resource-typesFrom the FHIR Standard | |
| Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:SystolicBP.dataAbsentReason.coding:dataAbsentReasonFHIRCode | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:DiastolicBP.dataAbsentReason.coding:DABCodeFHIR | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:MeanArterialPressure.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard |
| Id | Grade | Path(s) | Details | Requirements |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
| dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
| vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
| vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanArterialPressure | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from ObservationBPCore
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | ObservationBPCore | FHIR Blood Pressure Profile | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Representation defined by the system |
![]() ![]() |
1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) | |
![]() ![]() |
S | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made |
![]() ![]() |
1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation | |
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
S | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Representation defined by the system |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
S | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Quantity | Vital Sign Value recorded with UCUM |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format | ||||
| Path | Conformance | ValueSet | URI |
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | |
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG |
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | ObservationBPCore | FHIR Blood Pressure Profile Constraints: obs-6, obs-7, vs-2 | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | |||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
SΣ | 0..* | Identifier | Business Identifier for observation | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
![]() ![]() |
Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
![]() ![]() |
?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) | ||||
![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | Representation defined by the system Fixed Value: Vital Signs | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 2..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 75367002 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
![]() ![]() |
SΣ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
![]() ![]() |
SΣC | 1..1 | dateTime | DateTime for measurement Constraints: vs-1 | ||||
![]() ![]() |
Σ | 0..1 | instant | Date/Time this version was made available | ||||
![]() ![]() |
SΣ | 1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation | ||||
![]() ![]() |
SΣC | 0..1 | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Open by type:$this | |||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure | ||||
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Site (required) | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
![]() ![]() |
0..1 | Reference(Specimen) | Specimen used for this observation | |||||
![]() ![]() |
S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL | ||||
![]() ![]() ![]() |
SΣ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). Fixed Value: Device | ||||
![]() ![]() ![]() |
Σ | 0..1 | Identifier | Logical reference, when literal reference is not known | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Text alternative for the resource | ||||
![]() ![]() |
C | 0..* | BackboneElement | Provides guide for interpretation Constraints: obs-3 | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
![]() ![]() ![]() |
0..1 | Range | Applicable age range, if relevant | |||||
![]() ![]() ![]() |
0..1 | string | Text based reference range in an observation | |||||
![]() ![]() |
Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Used when reporting vital signs panel components | ||||
![]() ![]() |
Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
![]() ![]() |
SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system Constraints: vs-3 | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Systolic Blood Pressure | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271649006 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the systolic blood pressure must be within the range of 0-350 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Diastolic Blood Pressure | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271650006 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the diastolic blood pressure must be within the range of 0-200 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| Observation.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languagesFrom the FHIR Standard
| ||||
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | ||||
| Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1From the FHIR Standard | ||||
| Observation.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-typeFrom the FHIR Standard | ||||
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG | ||||
| Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | ||||
| Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | ||||
| Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-siteFrom the FHIR Standard | ||||
| Observation.bodySite.coding:BodySiteSCT | required | BPBodySitehttps://fhir.cambio.se/ValueSet/bp-body-site/v1From this IG | ||||
| Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methodsFrom the FHIR Standard | ||||
| Observation.device.type | extensible | Fixed Value: Devicehttp://hl7.org/fhir/ValueSet/resource-typesFrom the FHIR Standard | ||||
| Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaningFrom the FHIR Standard | ||||
| Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliestoFrom the FHIR Standard | ||||
| Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.dataAbsentReason.coding:dataAbsentReasonFHIRCode | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.dataAbsentReason.coding:DABCodeFHIR | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard |
| Id | Grade | Path(s) | Details | Requirements |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
| dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
| obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
| vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
| vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanArterialPressure | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from ObservationBPCore
Summary
Mandatory: 0 element(12 nested mandatory elements)
Must-Support: 22 elements
Fixed: 4 elements
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | ObservationBPCore | FHIR Blood Pressure Profile Constraints: obs-6, obs-7, vs-2 |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
0..0 | |||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
SΣ | 0..* | Identifier | Business Identifier for observation |
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) |
![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
![]() ![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | Representation defined by the system Fixed Value: Vital Signs |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() |
Σ | 2..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 75367002 |
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
![]() ![]() |
SΣ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made |
![]() ![]() |
SΣC | 1..1 | dateTime | DateTime for measurement Constraints: vs-1 |
![]() ![]() |
SΣ | 1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation |
![]() ![]() |
SΣC | 0..1 | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() |
time | |||
![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. |
![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Site (required) |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system |
![]() ![]() |
S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device |
![]() ![]() ![]() |
SΣ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). Fixed Value: Device |
![]() ![]() |
SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system Constraints: vs-3 |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Systolic Blood Pressure |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271649006 |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the systolic blood pressure must be within the range of 0-350 |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Diastolic Blood Pressure |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271650006 |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the diastolic blood pressure must be within the range of 0-200 |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format | ||||
| Path | Conformance | ValueSet / Code | URI |
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | |
| Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1From the FHIR Standard | |
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG | |
| Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | |
| Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | |
| Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-siteFrom the FHIR Standard | |
| Observation.bodySite.coding:BodySiteSCT | required | BPBodySitehttps://fhir.cambio.se/ValueSet/bp-body-site/v1From this IG | |
| Observation.device.type | extensible | Fixed Value: Devicehttp://hl7.org/fhir/ValueSet/resource-typesFrom the FHIR Standard | |
| Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:SystolicBP.dataAbsentReason.coding:dataAbsentReasonFHIRCode | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:DiastolicBP.dataAbsentReason.coding:DABCodeFHIR | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | |
| Observation.component:MeanArterialPressure.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | |
| Observation.component:MeanArterialPressure.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard |
| Id | Grade | Path(s) | Details | Requirements |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
| dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
| vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
| vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanArterialPressure | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
Differential View
This structure is derived from ObservationBPCore
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | ObservationBPCore | FHIR Blood Pressure Profile | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Representation defined by the system |
![]() ![]() |
1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) | |
![]() ![]() |
S | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made |
![]() ![]() |
1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation | |
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
S | 1..1 | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system |
![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Representation defined by the system |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
S | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | Quantity | Vital Sign Value recorded with UCUM |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | decimal | Numerical value (with implicit precision) |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | string | Unit representation |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() ![]() |
S | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] |
Documentation for this format | ||||
| Path | Conformance | ValueSet | URI |
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | |
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG |
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | ObservationBPCore | FHIR Blood Pressure Profile Constraints: obs-6, obs-7, vs-2 | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | |||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Position (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
SΣ | 0..* | Identifier | Business Identifier for observation | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() |
SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() |
SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
![]() ![]() |
Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
![]() ![]() |
?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: VitalSignStatus (required) | ||||
![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | Representation defined by the system Fixed Value: Vital Signs | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 2..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 75367002 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
![]() ![]() |
SΣ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
![]() ![]() |
SΣC | 1..1 | dateTime | DateTime for measurement Constraints: vs-1 | ||||
![]() ![]() |
Σ | 0..1 | instant | Date/Time this version was made available | ||||
![]() ![]() |
SΣ | 1..2 | Reference(Practitioner | PractitionerRole | Organization | Patient) | Who is responsible for the observation | ||||
![]() ![]() |
SΣC | 0..1 | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Open by type:$this | |||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() |
S | 0..1 | Annotation | Comment about the blood pressure | ||||
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: Blood Pressure Body Site (required) | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
![]() ![]() |
0..1 | Reference(Specimen) | Specimen used for this observation | |||||
![]() ![]() |
S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL | ||||
![]() ![]() ![]() |
SΣ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). Fixed Value: Device | ||||
![]() ![]() ![]() |
Σ | 0..1 | Identifier | Logical reference, when literal reference is not known | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Text alternative for the resource | ||||
![]() ![]() |
C | 0..* | BackboneElement | Provides guide for interpretation Constraints: obs-3 | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
![]() ![]() ![]() |
0..1 | Range | Applicable age range, if relevant | |||||
![]() ![]() ![]() |
0..1 | string | Text based reference range in an observation | |||||
![]() ![]() |
Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Used when reporting vital signs panel components | ||||
![]() ![]() |
Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
![]() ![]() |
SΣC | 2..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. Slice: Unordered, Open by value:code.coding.code, value:code.coding.system Constraints: vs-3 | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Systolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Systolic Blood Pressure | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271649006 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the systolic blood pressure must be within the range of 0-350 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 2..* | Coding | Diastolic Blood Pressure Slice: Unordered, Open by value:code, value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Diastolic Blood Pressure | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 271650006 | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Slice: Unordered, Closed by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | The value of the measured amount. The value of the diastolic blood pressure must be within the range of 0-200 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | Coding | Code defined by a terminology system Binding: DataAbsentReason (required) | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Used when reporting systolic and diastolic blood pressure. Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://snomed.info/sct | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 1285244000 | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Value recorded with UCUM Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Coded form of the unit Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format | ||||||||
| Path | Conformance | ValueSet / Code | URI | |||
| Observation.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languagesFrom the FHIR Standard
| ||||
| Observation.extension:bodyPosition.value[x].coding | required | BPBodyPositionhttps://fhir.cambio.se/ValueSet/bp-body-positionFrom this IG | ||||
| Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1From the FHIR Standard | ||||
| Observation.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-typeFrom the FHIR Standard | ||||
| Observation.status | required | VitalSignStatushttps://cambio.codes/fhir/vs/vital-sign-status/v1From this IG | ||||
| Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | ||||
| Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-categoryFrom the FHIR Standard | ||||
| Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-siteFrom the FHIR Standard | ||||
| Observation.bodySite.coding:BodySiteSCT | required | BPBodySitehttps://fhir.cambio.se/ValueSet/bp-body-site/v1From this IG | ||||
| Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methodsFrom the FHIR Standard | ||||
| Observation.device.type | extensible | Fixed Value: Devicehttp://hl7.org/fhir/ValueSet/resource-typesFrom the FHIR Standard | ||||
| Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaningFrom the FHIR Standard | ||||
| Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliestoFrom the FHIR Standard | ||||
| Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:SystolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.dataAbsentReason.coding:dataAbsentReasonFHIRCode | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:SystolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:DiastolicBP.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.dataAbsentReason.coding:DABCodeFHIR | required | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:DiastolicBP.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresultFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x] | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x]:valueQuantity | required | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1From the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reasonFrom the FHIR Standard | ||||
| Observation.component:MeanArterialPressure.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretationFrom the FHIR Standard |
| Id | Grade | Path(s) | Details | Requirements |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
| dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
| obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() | |
| vs-1 | error | Observation.effective[x] | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day : ($this as dateTime).toString().length() >= 8 | |
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. : (component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()) | |
| vs-3 | error | Observation.component, Observation.component:SystolicBP, Observation.component:DiastolicBP, Observation.component:MeanArterialPressure | If there is no a value a data absent reason must be present : value.exists() or dataAbsentReason.exists() |
This structure is derived from ObservationBPCore
Summary
Mandatory: 0 element(12 nested mandatory elements)
Must-Support: 22 elements
Fixed: 4 elements
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron